Quality Gas Combi Boiler with Smooth Flue Gas Discharge and Balanced Airflow Inside Combustion Chamber for Wide Proportional Modulation Range factory
<
Quality Gas Combi Boiler with Smooth Flue Gas Discharge and Balanced Airflow Inside Combustion Chamber for Wide Proportional Modulation Range factory
Quality Gas Combi Boiler with Smooth Flue Gas Discharge and Balanced Airflow Inside Combustion Chamber for Wide Proportional Modulation Range factory
Quality Gas Combi Boiler with Smooth Flue Gas Discharge and Balanced Airflow Inside Combustion Chamber for Wide Proportional Modulation Range factory
Quality Gas Combi Boiler with Smooth Flue Gas Discharge and Balanced Airflow Inside Combustion Chamber for Wide Proportional Modulation Range factory
>

Gas Combi Boiler with Smooth Flue Gas Discharge and Balanced Airflow Inside Combustion Chamber for Wide Proportional Modulation Range

Product Summary

Product Overview This wall-mounted combi gas boiler delivers smooth flue gas discharge and balanced airflow inside the combustion chamber. It combines touch-button operation, real-time water pressure monitoring, and a dual solenoid safety gas valve to ensure reliable and safe performance for ...

Product Custom Attributes

Modulation Range:
Wide Proportional Modulation Range
Condensate Pipe Material:
Acid-resistant Plastic Pipe
Post-purge Duration:
Flame Off Post-purge Program
Pre-purge Duration:
Pre-ignition Air Purge Program
Thermal Shock Resistance:
Resist Cyclic Temperature Change
Shell Flame Retardant Grade:
Flame Retardant Plastic Accessory
Display Fault Form:
Alphanumeric Fault Code
Anti-freeze Power Consumption:
Low Standby Anti-freeze Power
Multi-zone Control:
Dual Zone Hydraulic Module Match
Burner Cooling:
Air Cooling For Burner Body
Pressure Relief Component:
Spring Loaded Safety Valve
Highlight:

Smooth Flue Gas Discharge Gas Combi Boiler

,

Balanced Airflow Combustion Chamber Wall-Mounted Combi Boiler

,

Wide Proportional Modulation Range Gas Combi Boiler

Basic Properties

Place of Origin:
Zhongshan City, Guangdong Province, China
Brand Name:
SHUANGMEI
Certification:
CE, CSA, ISO9001.
Model Number:
TMSML1PB47

Trading Properties

Minimum Order Quantity:
100PCS
Price:
210-280 dollars
Packaging Details:
(Color) General Carton package with Foam. Packing size: 795x490x330mm
Delivery Time:
10-15days
Payment Terms:
L/C,D/A,D/P,T/T
Supply Ability:
20,000Pcs/Month

Product Description

Product Overview

This wall-mounted combi gas boiler delivers smooth flue gas discharge and balanced airflow inside the combustion chamber. It combines touch-button operation, real-time water pressure monitoring, and a dual solenoid safety gas valve to ensure reliable and safe performance for domestic hot water and heating applications.

Product Specifications
Product type Wall-mounted Combi Gas Boiler Place of Origin China
Logo customization Silk screen logo customization Panel operation Touch button operation
Flue wind resistance Anti-wind terminal cap Overheat protection Independent overheat thermostat
System air removal Automatic air vent valve Gas valve structure Dual solenoid safety valve
Gas tightness test Manual gas tightness inspection Water pressure detection Pressure sensor real-time monitoring
Sea freight suitability Anti-corrosion export package Capacity 12L / 13L / 14L / 16L / 18L / 20L
Thermostat wiring Two-core signal wire DHW Heat Exchanger Material Stainless steel plate
Customization Support OEM logo & outer carton customization Pump manifold Integrated pump manifold assembly
Certification CE Domestic hot water loop Independent secondary heat exchange loop
Combustion chamber lining High temperature insulation lining Static sealing test Static sealing inspection before delivery
Flow switch response Quick trigger for water demand Sealing material FKM fluororubber gasket
Key Features
  • The system supports diluted glycol adding for anti-freeze protection in extremely cold regions.
  • Touch button panel brings a simple and sensitive operation experience for end users.
  • The flue terminal is wind-resistant to avoid flameout caused by strong outdoor wind.
  • The boiler is designed for indoor wall mounting only to guarantee safe operation.
  • Transient voltage suppression module protects the circuit from sudden voltage surges.
  • Gas pressure sensor keeps tracking inlet gas pressure continuously. If gas pressure is too high or too low beyond the working range, the boiler will alarm and stop gas supply. This avoids incomplete combustion caused by insufficient gas pressure or flame lift from excessive gas pressure.
Precision Temperature Sensing

This combi gas boiler uses high-precision temperature sensors with a narrow tolerance range. The temperature probes adopt NTC thermistor elements encapsulated in a stainless steel sleeve, providing fast response to water temperature changes and good resistance to corrosion. The supply and return temperature sensors are installed on the heating circuit, while separate sensors monitor domestic hot water inlet and outlet. Multiple temperature measuring points allow the mainboard to draw an accurate picture of the system working condition.

If any temperature probe becomes loose or damaged, the boiler will detect the abnormal reading, trigger a fault alarm, and stop combustion automatically to prevent unsafe operation. The sensor signal cable uses shielding wire to resist external electromagnetic interference. Temperature sensors are pre-calibrated at the factory, so no extra calibration is required after onsite installation, simplifying commissioning work for installers.

Frequently Asked Questions
Q1: What material is the domestic hot water plate heat exchanger?

A1: The secondary plate heat exchanger adopts a stainless steel welding structure.

Q2: Can the boiler detect a gas leakage signal from an external alarm?

A2: It reserves a signal input port to link an external gas leakage detector.

Q3: Does the unit have a soft ignition function to reduce impact sound?

A3: Soft ignition control reduces ignition impact noise effectively.

Q4: What protection works when the flame signal is lost suddenly?

A4: Flame loss protection cuts the gas valve immediately and reports a fault code.

Q5: Can the boiler keep running when only a small heating load is needed?

A5: The modulating burner adjusts fire power down to the minimum load steadily.

Q6: Does the boiler have backflow prevention for flue gas?

A6: An anti-backflow structure inside the flue connector prevents flue gas reflow.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.